![]() | 15808023761 15808023760 023-47546974 |
手機:15808023761
15808023760
電話:023-47546974
網址(zhi):lianghm.cn
地址:重慶市江津(jin)區雙福新區福星大道937號鑫成瑞暖通廠區
1,通風(feng)(feng)風(feng)(feng)管(guan)(guan)(guan)安(an)裝(zhuang)在(zai)支架上,應設(she)托座。2,通風(feng)(feng)風(feng)(feng)管(guan)(guan)(guan)如(ru)有(you)穿出屋(wu)面外部分,應設(she)置防雨罩。3,通風(feng)(feng)風(feng)(feng)管(guan)(guan)(guan)采用(yong)無法(fa)蘭連(lian)時(shi),接(jie)(jie)口處應嚴密(mi)牢固。通風(feng)(feng)風(feng)(feng)管(guan)(guan)(guan)連(lian)接(jie)(jie)兩平面應平直,不(bu)得(de)錯位及扭曲。4,輸送易產生冷凝水(shui)的(de)(de)(de)通風(feng)(feng)風(feng)(feng)管(guan)(guan)(guan),安(an)裝(zhuang)應設(she)計坡(po)度。通風(feng)(feng)風(feng)(feng)管(guan)(guan)(guan)底部不(bu)能有(you)縱向(xiang)的(de)(de)(de)接(jie)(jie)縫, 如(ru)必須(xu)有(you)接(jie)(jie)縫,則應采用(yong)密(mi)封方(fang)式(shi)。通風(feng)(feng)管(guan)(guan)(guan)道安(an)裝(zhuang)完(wan)畢后,應進行嚴密(mi)性試驗(yan),如(ru)發現異常情況,通風(feng)(feng)管(guan)(guan)(guan)道的(de)(de)(de)制作、安(an)裝(zhuang)、檢驗(yan)和試驗(yan),是一個連(lian)貫的(de)(de)(de)工程(cheng),做到安(an)全適用(yong),經濟合理,方(fang)便施工,確(que)保通風(feng)(feng)管(guan)(guan)(guan)道的(de)(de)(de)工程(cheng)質量(liang)。
消防排煙機一般是采用離心式風機和軸流式風機兩種重要的型式。從消防排煙風機風量、風壓考慮來看,消防排煙風機是高比轉高效率的風機,更加的適合選用軸流風機。軸流式消防排煙風機有兩種設計型式,一種為電機與主氣流分離型式,另一種為電機置于主氣流之中。九龍坡通風管根據煙氣溫度的不同,采用不同型式的消防排煙風機,溫度大于400℃時,采用電機與主氣流分離型式,溫度小于400℃大于150℃,兩種型式的電機都可以選擇,在溫度小于150℃的時候,采用電機置于主氣流之中。 軸流消防排煙風機的流量范圍從7200m?/h至110000m?/h,有不同型號的編制,通風管用(yong)(yong)來滿(man)足不同通風(feng)排(pai)(pai)煙(yan)流(liu)量的(de)(de)(de)需求。消(xiao)(xiao)防排(pai)(pai)煙(yan)風(feng)機(ji)可(ke)(ke)以根據壓(ya)力(li)情況的(de)(de)(de)不同分為(wei)(wei)兩種(zhong)類(lei)(lei)型(xing),一類(lei)(lei)為(wei)(wei)軸流(liu)式消(xiao)(xiao)防排(pai)(pai)煙(yan)機(ji),其各機(ji)號的(de)(de)(de)壓(ya)力(li)在(zai)600Pa左(zuo)(zuo)右,另一類(lei)(lei)為(wei)(wei)斜流(liu)消(xiao)(xiao)防排(pai)(pai)煙(yan)風(feng)機(ji),各機(ji)號的(de)(de)(de)壓(ya)力(li)在(zai)1000Pa左(zuo)(zuo)右。為(wei)(wei)了(le)滿(man)足排(pai)(pai)煙(yan)量和(he)通風(feng)換氣的(de)(de)(de)要求,消(xiao)(xiao)防排(pai)(pai)煙(yan)風(feng)機(ji)一般(ban)都設計(ji)了(le)雙(shuang)速型(xing)的(de)(de)(de)結構模式。低速可(ke)(ke)以通風(feng)使用(yong)(yong),高速可(ke)(ke)以排(pai)(pai)放煙(yan)霧,這樣(yang)不但可(ke)(ke)以節約(yue)能(neng)源同時(shi)又降低了(le)噪聲污染。
防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)的(de)外觀,防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)應(ying)外觀完好無損,機(ji)械(xie)部(bu)分(fen)外表無銹蝕、變形(xing)或機(ji)械(xie)損傷。在(zai)其明顯部(bu)位(wei)(wei)(wei)(wei)設置永久性(xing)標(biao)(biao)牌,標(biao)(biao)明產品(pin)名稱(cheng)、型(xing)號、規格、耐火(huo)(huo)性(xing)能(neng)及(ji)商標(biao)(biao)、生(sheng)(sheng)產單位(wei)(wei)(wei)(wei)(制造商)名稱(cheng)和廠址、出日期及(ji)產品(pin)生(sheng)(sheng)產批號、執(zhi)行標(biao)(biao)準等(deng),內(nei)容清晰,設置牢靠。防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)的(de)安裝位(wei)(wei)(wei)(wei)置防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)主要安裝在(zai)風(feng)(feng)(feng)(feng)管(guan)靠近防(fang)(fang)(fang)(fang)火(huo)(huo)分(fen)隔處(chu),暗裝時,安裝部(bu)位(wei)(wei)(wei)(wei)應(ying)設置方便(bian)維護(hu)的(de)檢(jian)修口。具(ju)體檢(jian)查要求(qiu)為:(1)通(tong)風(feng)(feng)(feng)(feng)、空(kong)調系(xi)統(tong)(tong)的(de)風(feng)(feng)(feng)(feng)管(guan),在(zai)以下部(bu)位(wei)(wei)(wei)(wei)應(ying)設置公稱(cheng)動作溫度為70℃的(de)防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa):①穿(chuan)(chuan)越(yue)(yue)防(fang)(fang)(fang)(fang)火(huo)(huo)分(fen)區(qu)(qu)處(chu);②穿(chuan)(chuan)越(yue)(yue)通(tong)風(feng)(feng)(feng)(feng)、空(kong)調機(ji)房(fang)(fang)的(de)房(fang)(fang)間隔墻(qiang)(qiang)和樓(lou)板(ban)處(chu);③穿(chuan)(chuan)越(yue)(yue)重要或火(huo)(huo)災(zai)危(wei)險性(xing)大的(de)房(fang)(fang)間隔墻(qiang)(qiang)和樓(lou)板(ban)處(chu);④穿(chuan)(chuan)越(yue)(yue)防(fang)(fang)(fang)(fang)火(huo)(huo)分(fen)隔處(chu)的(de)變形(xing)縫兩側(ce);⑤豎向(xiang)風(feng)(feng)(feng)(feng)管(guan)與(yu)每層水平(ping)風(feng)(feng)(feng)(feng)管(guan)交(jiao)接(jie)處(chu)的(de)水平(ping)管(guan)段上。當建(jian)筑(zhu)內(nei)每個防(fang)(fang)(fang)(fang)火(huo)(huo)分(fen)區(qu)(qu)的(de)通(tong)風(feng)(feng)(feng)(feng)、空(kong)調系(xi)統(tong)(tong)均獨立設置時,水平(ping)風(feng)(feng)(feng)(feng)管(guan)與(yu)豎向(xiang)總(zong)管(guan)的(de)交(jiao)接(jie)處(chu)可不設置防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)。(2)公共建(jian)筑(zhu)的(de)浴室、衛生(sheng)(sheng)間和廚房(fang)(fang)的(de)豎向(xiang)排(pai)風(feng)(feng)(feng)(feng)管(guan),應(ying)采取防(fang)(fang)(fang)(fang)止回流(liu)措施,并宜(yi)在(zai)支管(guan)上設置防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)。(3)公共建(jian)筑(zhu)內(nei)廚房(fang)(fang)的(de)排(pai)油煙管(guan)道(dao),宜(yi)按防(fang)(fang)(fang)(fang)火(huo)(huo)分(fen)區(qu)(qu)設置,且在(zai)與(yu)豎向(xiang)排(pai)風(feng)(feng)(feng)(feng)管(guan)連接(jie)的(de)支管(guan)處(chu)應(ying)設置防(fang)(fang)(fang)(fang)火(huo)(huo)閥(fa)。
1、 薄(bo)鋼(gang)板(ban)矩形(xing)風(feng)管的(de)(de)(de)剛度不(bu)夠,表(biao)(biao)現形(xing)式:風(feng)管的(de)(de)(de)大(da)邊上下(xia)有(you)不(bu)同程度的(de)(de)(de)下(xia)沉(chen),兩(liang)側面(mian)小邊稍向外凸(tu)出,有(you)明顯的(de)(de)(de)變形(xing)。對(dui)產(chan)(chan)生的(de)(de)(de)原(yuan)因分析:① 制作(zuo)風(feng)管的(de)(de)(de)鋼(gang)板(ban)厚(hou)度不(bu)符合施工及驗(yan)收(shou)規(gui)范的(de)(de)(de)要(yao)求;② 咬口的(de)(de)(de)形(xing)式選擇不(bu)當;③ 沒有(you)按照《施工及驗(yan)收(shou)規(gui)范》要(yao)求,對(dui)于(yu)邊長(chang)≥630 mm或(huo)(huo)保溫風(feng)管≥800 mm,其(qi)管長(chang)在1 200mm以上,均應采取加(jia)固措施。2 、薄(bo)鋼(gang)板(ban)矩形(xing)風(feng)管扭曲、翹(qiao)角,表(biao)(biao)現形(xing)式:風(feng)管表(biao)(biao)面(mian)不(bu)平(ping)(ping);對(dui)角線(xian)不(bu)相(xiang)(xiang)等;相(xiang)(xiang)鄰表(biao)(biao)面(mian)互不(bu)垂直(zhi);兩(liang)相(xiang)(xiang)對(dui)表(biao)(biao)面(mian)不(bu)平(ping)(ping)行及兩(liang)管端平(ping)(ping)面(mian)不(bu)平(ping)(ping)行等。產(chan)(chan)生的(de)(de)(de)原(yuan)因分析:① 矩形(xing)板(ban)料下(xia)料后,未(wei)對(dui)四個(ge)角進行嚴格的(de)(de)(de)角方測量;② 風(feng)管的(de)(de)(de)大(da)邊或(huo)(huo)小邊的(de)(de)(de)兩(liang)個(ge)相(xiang)(xiang)對(dui)面(mian)的(de)(de)(de)板(ban)料長(chang)度和(he)寬度不(bu)相(xiang)(xiang)等;③ 風(feng)管的(de)(de)(de)四個(ge)角處的(de)(de)(de)咬口寬度不(bu)相(xiang)(xiang)等;④ 手工咬口合縫受力不(bu)均。