![]() | 15808023761 15808023760 023-47546974 |
手機:15808023761
15808023760
電話:023-47546974
網址:lianghm.cn
地(di)址:重慶市江津(jin)區(qu)雙福(fu)新區(qu)福(fu)星(xing)大道937號鑫成瑞暖通(tong)廠區(qu)
雖然在商(shang)業建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)與(yu)多(duo)種居(ju)(ju)住房的(de)(de)(de)被動消(xiao)防中(zhong)(zhong),防火(huo)(huo)(huo)閥是關鍵組件,但在對(dui)建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)和其居(ju)(ju)住者的(de)(de)(de)安(an)全保護(hu)中(zhong)(zhong),很多(duo)管(guan)理者沒有(you)意識到防火(huo)(huo)(huo)閥的(de)(de)(de)作(zuo)用(yong)(yong)(yong)以及(ji)規定時間(jian)(jian)間(jian)(jian)隔(ge)(ge)內,防火(huo)(huo)(huo)閥的(de)(de)(de)檢測、清潔及(ji)維護(hu)的(de)(de)(de)重要意義(yi)。在商(shang)業建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)中(zhong)(zhong)的(de)(de)(de)建(jian)(jian)(jian)(jian)(jian)造中(zhong)(zhong)我們總會遇到一(yi)些麻煩,試(shi)圖在能源效率(lv)與(yu)室內空(kong)氣質(zhi)量之間(jian)(jian)尋求(qiu)平(ping)衡(heng)就(jiu)是其中(zhong)(zhong)。大多(duo)商(shang)業建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)通(tong)(tong)過機(ji)械通(tong)(tong)風(feng)或空(kong)調系統(tong)解決,能夠測量和控制整(zheng)個建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)的(de)(de)(de)空(kong)氣變化。在通(tong)(tong)風(feng)管(guan)道系統(tong)的(de)(de)(de)安(an)裝上(shang)就(jiu)存在上(shang)面提到的(de)(de)(de)問題———如(ru)何在延(yan)遲(chi)或阻(zu)止(zhi)火(huo)(huo)(huo)災蔓(man)延(yan)的(de)(de)(de)建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)防火(huo)(huo)(huo)分隔(ge)(ge)與(yu)所允許(xu)空(kong)氣自(zi)由流(liu)(liu)通(tong)(tong)的(de)(de)(de)需要之間(jian)(jian)達(da)到平(ping)衡(heng)。滿足空(kong)氣自(zi)由流(liu)(liu)通(tong)(tong)需要不可避(bi)免地再引入一(yi)條(tiao)通(tong)(tong)道,而這(zhe)卻加(jia)快(kuai)了(le)(le)火(huo)(huo)(huo)勢的(de)(de)(de)蔓(man)延(yan)———利(li)用(yong)(yong)(yong)通(tong)(tong)風(feng)管(guan)道系統(tong)使用(yong)(yong)(yong)的(de)(de)(de)通(tong)(tong)道。毫無(wu)疑問,這(zhe)中(zhong)(zhong)斷了(le)(le)防火(huo)(huo)(huo)分隔(ge)(ge),充當了(le)(le)建(jian)(jian)(jian)(jian)(jian)筑(zhu)(zhu)(zhu)被動消(xiao)防護(hu)面的(de)(de)(de)“裂口”。
層(ceng)高(gao)(gao)(gao)(gao)過高(gao)(gao)(gao)(gao)如何提(ti)高(gao)(gao)(gao)(gao)制冷(leng)效果,解決方(fang)案:較(jiao)(jiao)之于常(chang)規層(ceng)高(gao)(gao)(gao)(gao)的(de)房屋(一(yi)般(ban)為2.6-2.7米(mi)左右)。別墅(shu)的(de)層(ceng)高(gao)(gao)(gao)(gao)一(yi)般(ban)都為3米(mi)甚至以(yi)上的(de)高(gao)(gao)(gao)(gao)度。此前提(ti)下中央(yang)空調制冷(leng)和采暖的(de)配(pei)比較(jiao)(jiao)之于一(yi)般(ban)層(ceng)高(gao)(gao)(gao)(gao)的(de)房屋會(hui)更高(gao)(gao)(gao)(gao)。如一(yi)般(ban)平(ping)(ping)(ping)層(ceng)的(de)配(pei)比為200w/平(ping)(ping)(ping)方(fang)。別墅(shu)為230-280w/平(ping)(ping)(ping)方(fang)。空調外機需要如何擺(bai)放較(jiao)(jiao)為合理,解決方(fang)案:別墅(shu)由于面(mian)積較(jiao)(jiao)大,較(jiao)(jiao)之于平(ping)(ping)(ping)層(ceng)一(yi)般(ban)外機的(de)功率(lv)較(jiao)(jiao)大。體積也就較(jiao)(jiao)之平(ping)(ping)(ping)層(ceng)會(hui)更大。一(yi)般(ban)的(de)擺(bai)放位(wei)置位(wei)于本身建筑的(de)自留(liu)機位(wei)或(huo)者位(wei)于門口或(huo)者陽(yang)臺(tai)花園的(de)平(ping)(ping)(ping)臺(tai)之上。鋪設(she)可供平(ping)(ping)(ping)衡(heng)的(de)水泥臺(tai)面(mian)即(ji)可。
1、 薄(bo)(bo)鋼板矩形(xing)風(feng)管(guan)的(de)(de)(de)剛度(du)(du)不(bu)(bu)夠,表(biao)(biao)現形(xing)式:風(feng)管(guan)的(de)(de)(de)大(da)(da)邊(bian)上(shang)(shang)下有(you)不(bu)(bu)同(tong)程度(du)(du)的(de)(de)(de)下沉,兩(liang)(liang)側面(mian)小邊(bian)稍向外凸出,有(you)明顯的(de)(de)(de)變形(xing)。對(dui)產生的(de)(de)(de)原因分析:① 制作風(feng)管(guan)的(de)(de)(de)鋼板厚度(du)(du)不(bu)(bu)符合施(shi)工(gong)及驗收規(gui)范的(de)(de)(de)要求(qiu);② 咬口的(de)(de)(de)形(xing)式選擇不(bu)(bu)當;③ 沒有(you)按照《施(shi)工(gong)及驗收規(gui)范》要求(qiu),對(dui)于邊(bian)長≥630 mm或(huo)保(bao)溫(wen)風(feng)管(guan)≥800 mm,其管(guan)長在1 200mm以上(shang)(shang),均應采取加固措施(shi)。2 、薄(bo)(bo)鋼板矩形(xing)風(feng)管(guan)扭曲、翹角,表(biao)(biao)現形(xing)式:風(feng)管(guan)表(biao)(biao)面(mian)不(bu)(bu)平;對(dui)角線不(bu)(bu)相等(deng)(deng);相鄰(lin)表(biao)(biao)面(mian)互不(bu)(bu)垂直;兩(liang)(liang)相對(dui)表(biao)(biao)面(mian)不(bu)(bu)平行(xing)及兩(liang)(liang)管(guan)端(duan)平面(mian)不(bu)(bu)平行(xing)等(deng)(deng)。產生的(de)(de)(de)原因分析:① 矩形(xing)板料(liao)下料(liao)后,未對(dui)四(si)個(ge)(ge)角進行(xing)嚴格的(de)(de)(de)角方測量;② 風(feng)管(guan)的(de)(de)(de)大(da)(da)邊(bian)或(huo)小邊(bian)的(de)(de)(de)兩(liang)(liang)個(ge)(ge)相對(dui)面(mian)的(de)(de)(de)板料(liao)長度(du)(du)和寬度(du)(du)不(bu)(bu)相等(deng)(deng);③ 風(feng)管(guan)的(de)(de)(de)四(si)個(ge)(ge)角處的(de)(de)(de)咬口寬度(du)(du)不(bu)(bu)相等(deng)(deng);④ 手工(gong)咬口合縫受力不(bu)(bu)均。
一、火災自動報警系統:對消防火災報警控制器進行自檢功能檢查:對可測量相關參數進行查看和記錄,如回路電流等;公共場所煙感器、溫感器安裝檢查,與底座接觸是否良好,外觀是否潔凈完好;每次隨機抽取不低于5%的煙感或溫感,噴煙或加熱后查視報警是否正確;手動報警按鈕,云南通風管檢查安裝是否牢固,有無破損及丟失;每次隨機抽取不低于5%的手動報警按鈕,進行模擬報警,測試報警功能是否正常;對樓層內各模塊箱進行外觀檢查,外接線是否固定良好;通風管批發對(dui)聯(lian)動控制(zhi)柜(ju)上的按(an)鈕每次按(an)10%的比例(li)進(jin)行(xing)(xing)(xing)功能試(shi)驗(yan),控制(zhi)功能正常。對(dui)火(huo)災(zai)報警控制(zhi)柜(ju)、聯(lian)動控制(zhi)柜(ju)等進(jin)行(xing)(xing)(xing)清掃(sao)除塵(chen)。線(xian)路松動,應進(jin)行(xing)(xing)(xing)緊固。對(dui)自檢(jian)、消音、復(fu)位(wei)功能檢(jian)查,主電(dian)源與備用(yong)電(dian)源切換(huan)、報警檢(jian)查。二、應急照明及(ji)疏散指示(shi)燈(deng)(deng)每3個月進(jin)行(xing)(xing)(xing)一次備用(yong)電(dian)池(chi)亮燈(deng)(deng)(半個小時),使電(dian)池(chi)放電(dian)后(hou)再(zai)(zai)充(chong)電(dian),延長電(dian)池(chi)壽命;檢(jian)查出(chu)口指示(shi)燈(deng)(deng)玻璃面板(ban)有無劃(hua)傷或破裂現象;出(chu)口指示(shi)燈(deng)(deng)電(dian)源指示(shi)燈(deng)(deng)是否亮,如(ru)不(bu)亮,應立即修理(li);檢(jian)查出(chu)口指示(shi)燈(deng)(deng)安裝是否牢(lao)固;針對(dui)檢(jian)查中發現的缺陷取下來進(jin)行(xing)(xing)(xing)修復(fu),再(zai)(zai)裝回原位(wei);燈(deng)(deng)箱外殼及(ji)面板(ban)擦抹干凈。