![]() | 15808023761 15808023760 023-47546974 |
手(shou)機:15808023761
15808023760
電話:023-47546974
網址:lianghm.cn
地址:重慶市江津區雙福(fu)新區福(fu)星大(da)道937號鑫成(cheng)瑞(rui)暖通廠區
一(yi)、火災自(zi)動(dong)報警系統:對(dui)(dui)(dui)(dui)消防(fang)火災報警控(kong)制(zhi)器(qi)進(jin)(jin)(jin)行(xing)(xing)自(zi)檢(jian)(jian)(jian)(jian)功(gong)能檢(jian)(jian)(jian)(jian)查(cha):對(dui)(dui)(dui)(dui)可(ke)測量相(xiang)關(guan)參數進(jin)(jin)(jin)行(xing)(xing)查(cha)看(kan)和(he)記錄(lu),如回路(lu)(lu)電(dian)(dian)流等;公共場所煙(yan)感(gan)(gan)器(qi)、溫(wen)感(gan)(gan)器(qi)安(an)裝(zhuang)檢(jian)(jian)(jian)(jian)查(cha),與(yu)底座接觸是(shi)(shi)(shi)否(fou)(fou)良(liang)好(hao)(hao),外(wai)(wai)觀是(shi)(shi)(shi)否(fou)(fou)潔凈完(wan)好(hao)(hao);每(mei)次(ci)隨(sui)機(ji)抽(chou)取(qu)不(bu)低于5%的(de)煙(yan)感(gan)(gan)或溫(wen)感(gan)(gan),噴煙(yan)或加熱后(hou)查(cha)視報警是(shi)(shi)(shi)否(fou)(fou)正確;手(shou)動(dong)報警按鈕,檢(jian)(jian)(jian)(jian)查(cha)安(an)裝(zhuang)是(shi)(shi)(shi)否(fou)(fou)牢(lao)固,有(you)(you)無破(po)損及(ji)丟失;每(mei)次(ci)隨(sui)機(ji)抽(chou)取(qu)不(bu)低于5%的(de)手(shou)動(dong)報警按鈕,進(jin)(jin)(jin)行(xing)(xing)模擬報警,測試(shi)報警功(gong)能是(shi)(shi)(shi)否(fou)(fou)正常(chang);對(dui)(dui)(dui)(dui)樓層內各模塊(kuai)箱(xiang)進(jin)(jin)(jin)行(xing)(xing)外(wai)(wai)觀檢(jian)(jian)(jian)(jian)查(cha),外(wai)(wai)接線是(shi)(shi)(shi)否(fou)(fou)固定良(liang)好(hao)(hao);對(dui)(dui)(dui)(dui)聯動(dong)控(kong)制(zhi)柜上的(de)按鈕每(mei)次(ci)按10%的(de)比例(li)進(jin)(jin)(jin)行(xing)(xing)功(gong)能試(shi)驗,控(kong)制(zhi)功(gong)能正常(chang)。對(dui)(dui)(dui)(dui)火災報警控(kong)制(zhi)柜、聯動(dong)控(kong)制(zhi)柜等進(jin)(jin)(jin)行(xing)(xing)清掃除塵。線路(lu)(lu)松動(dong),應進(jin)(jin)(jin)行(xing)(xing)緊固。對(dui)(dui)(dui)(dui)自(zi)檢(jian)(jian)(jian)(jian)、消音、復位功(gong)能檢(jian)(jian)(jian)(jian)查(cha),主(zhu)電(dian)(dian)源(yuan)(yuan)與(yu)備用(yong)電(dian)(dian)源(yuan)(yuan)切換、報警檢(jian)(jian)(jian)(jian)查(cha)。二(er)、應急(ji)照明及(ji)疏散指(zhi)示(shi)(shi)燈(deng)每(mei)3個月進(jin)(jin)(jin)行(xing)(xing)一(yi)次(ci)備用(yong)電(dian)(dian)池(chi)亮燈(deng)(半個小時),使電(dian)(dian)池(chi)放電(dian)(dian)后(hou)再(zai)充電(dian)(dian),延長電(dian)(dian)池(chi)壽(shou)命;檢(jian)(jian)(jian)(jian)查(cha)出(chu)口指(zhi)示(shi)(shi)燈(deng)玻璃面(mian)板有(you)(you)無劃傷或破(po)裂現象;出(chu)口指(zhi)示(shi)(shi)燈(deng)電(dian)(dian)源(yuan)(yuan)指(zhi)示(shi)(shi)燈(deng)是(shi)(shi)(shi)否(fou)(fou)亮,如不(bu)亮,應立即修理;檢(jian)(jian)(jian)(jian)查(cha)出(chu)口指(zhi)示(shi)(shi)燈(deng)安(an)裝(zhuang)是(shi)(shi)(shi)否(fou)(fou)牢(lao)固;針對(dui)(dui)(dui)(dui)檢(jian)(jian)(jian)(jian)查(cha)中發現的(de)缺陷取(qu)下來(lai)進(jin)(jin)(jin)行(xing)(xing)修復,再(zai)裝(zhuang)回原位;燈(deng)箱(xiang)外(wai)(wai)殼及(ji)面(mian)板擦抹干(gan)凈。
一(yi)、風(feng)管(guan)(guan)(guan)(guan)(guan)及部件安(an)(an)裝(zhuang)的(de)(de)有(you)(you)關規(gui)定(ding)1.風(feng)管(guan)(guan)(guan)(guan)(guan)安(an)(an)裝(zhuang)的(de)(de)強制規(gui)定(ding),當(dang)風(feng)管(guan)(guan)(guan)(guan)(guan)穿過需要封閉的(de)(de)防火、防爆墻(qiang)體(ti)或(huo)(huo)(huo)(huo)樓板時(shi)(shi),應設(she)預埋(mai)管(guan)(guan)(guan)(guan)(guan)或(huo)(huo)(huo)(huo)防護(hu)套管(guan)(guan)(guan)(guan)(guan)。套管(guan)(guan)(guan)(guan)(guan)鋼板厚度(du)不應小(xiao)于1.6mm,風(feng)管(guan)(guan)(guan)(guan)(guan)與防護(hu)套管(guan)(guan)(guan)(guan)(guan)之間應用不燃(ran)且對人體(ti)無(wu)害的(de)(de)柔性材(cai)料封堵,風(feng)道應安(an)(an)裝(zhuang)設(she)防火閥。風(feng)管(guan)(guan)(guan)(guan)(guan)內(nei)嚴(yan)(yan)禁各種管(guan)(guan)(guan)(guan)(guan)道、電線敷設(she)及穿越;輸送含(han)有(you)(you)易(yi)燃(ran)易(yi)爆氣體(ti)或(huo)(huo)(huo)(huo)安(an)(an)裝(zhuang)在(zai)(zai)易(yi)燃(ran)易(yi)爆環境的(de)(de)風(feng)管(guan)(guan)(guan)(guan)(guan)系統(tong),應有(you)(you)良好的(de)(de)接(jie)(jie)地,通過生活區、生產房間時(shi)(shi)必須嚴(yan)(yan)密,不得設(she)接(jie)(jie)口;室外主管(guan)(guan)(guan)(guan)(guan)的(de)(de)固定(ding)拉索嚴(yan)(yan)禁拉在(zai)(zai)避雷(lei)針或(huo)(huo)(huo)(huo)避雷(lei)網上。輸送溫度(du)高于80℃的(de)(de)空氣的(de)(de)風(feng)管(guan)(guan)(guan)(guan)(guan),應按設(she)計要求采(cai)取防護(hu)措(cuo)施(shi)(shi)。2.風(feng)管(guan)(guan)(guan)(guan)(guan)安(an)(an)裝(zhuang)的(de)(de)一(yi)般規(gui)定(ding)風(feng)管(guan)(guan)(guan)(guan)(guan)安(an)(an)裝(zhuang)宜在(zai)(zai)建筑圍護(hu)結構施(shi)(shi)工完畢(bi)、場(chang)所清理后(hou)(hou)進(jin)行。凈化空調風(feng)管(guan)(guan)(guan)(guan)(guan)應在(zai)(zai)安(an)(an)裝(zhuang)部位(wei)地面(mian)(mian)做好,墻(qiang)面(mian)(mian)抹(mo)灰工序完畢(bi),室內(nei)無(wu)飛塵(chen)或(huo)(huo)(huo)(huo)有(you)(you)防塵(chen)措(cuo)施(shi)(shi)后(hou)(hou)進(jin)行。安(an)(an)裝(zhuang)風(feng)管(guan)(guan)(guan)(guan)(guan)前應清除(chu)管(guan)(guan)(guan)(guan)(guan)內(nei)外雜物,并做好清潔(jie)和保護(hu)工作,風(feng)管(guan)(guan)(guan)(guan)(guan)安(an)(an)裝(zhuang)的(de)(de)位(wei)置、標高和走向等應符(fu)合設(she)計要求,現場(chang)風(feng)管(guan)(guan)(guan)(guan)(guan)接(jie)(jie)口的(de)(de)配置不得縮(suo)小(xiao)有(you)(you)效截(jie)面(mian)(mian)。
現階段(duan)是(shi)很多雞(ji)(ji)舍都配(pei)(pei)備了(le)通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan),我是(shi)2013年開(kai)始用(yong)(yong)的通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan),在使用(yong)(yong)過(guo)(guo)程(cheng)中,曾經出(chu)現過(guo)(guo)很多問題,現總結一下(xia)(xia),歡(huan)迎拍磚(zhuan)交(jiao)流。一,通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)的作用(yong)(yong)。1降低(di)(di)操作負壓(ya)。冬季沒安裝通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)的雞(ji)(ji)舍,使用(yong)(yong)小窗通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng),尤其是(shi)跨度大的雞(ji)(ji)舍為了(le)導(dao)風(feng)(feng)(feng)(feng)(feng)(feng)合理安全(quan),使用(yong)(yong)高負壓(ya)通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)。而(er)使用(yong)(yong)通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)道,由于(yu)進風(feng)(feng)(feng)(feng)(feng)(feng)在管(guan)(guan)(guan)道內基(ji)本不(bu)擴散,低(di)(di)負壓(ya)下(xia)(xia)都是(shi)按照(zhao)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)方向,依次(ci)從開(kai)口(kou)處出(chu)風(feng)(feng)(feng)(feng)(feng)(feng)。2位置高,出(chu)風(feng)(feng)(feng)(feng)(feng)(feng)均勻。進風(feng)(feng)(feng)(feng)(feng)(feng)雖然在管(guan)(guan)(guan)道內沒有預熱,但下(xia)(xia)落位置高,向下(xia)(xia)擴散時間就(jiu)是(shi)預熱過(guo)(guo)程(cheng)。3跟風(feng)(feng)(feng)(feng)(feng)(feng)機(ji)配(pei)(pei)合合理配(pei)(pei)置,在初始開(kai)啟風(feng)(feng)(feng)(feng)(feng)(feng)機(ji)階段(duan),由于(yu)設計問題導(dao)致進風(feng)(feng)(feng)(feng)(feng)(feng)窗使用(yong)(yong)不(bu)安全(quan),可以利用(yong)(yong)通(tong)(tong)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)過(guo)(guo)渡。
確保通風效果:高溫消防排煙風機的使用介質本身溫度相對較高,且自身的運轉也是會產生一定的溫度,若是將其放在密封環境中,那么很容易就會導致高溫現象發生,針對于這種情況在前期選擇安裝環境時就應該要多注意,好是能夠將其放在通風效果較好的環境中,通過對流運動來有效降低溫度,這是可以有效的防止高溫現象的發生。排煙管道價格確保電流大小合適:消防排煙風機的使用還是要注意電流問題,是應該要防止電流過大現象發生,否則會讓排煙管道在運行中會(hui)因為電(dian)流過大而(er)產生較多的(de)電(dian)阻,而(er)這也是會(hui)導致(zhi)高(gao)溫現象(xiang)發生。因為高(gao)溫會(hui)直接影(ying)響著消防排煙(yan)風(feng)機(ji)的(de)使(shi)用(yong),因此在日常使(shi)用(yong)中就應(ying)該要(yao)采取(qu)措施(shi)來有效的(de)防止高(gao)溫現象(xiang)發生,且在高(gao)溫之(zhi)后要(yao)采取(qu)措施(shi)來降溫,以確保(bao)安全(quan)。