消(xiao)(xiao)聲(sheng)(sheng)(sheng)器(qi)是(shi)利(li)用(yong)聲(sheng)(sheng)(sheng)的(de)(de)吸(xi)收(shou)、反射(she)、干涉等原(yuan)理,降低通風與空調系統(tong)中氣流(liu)噪聲(sheng)(sheng)(sheng)的(de)(de)裝置。根據消(xiao)(xiao)聲(sheng)(sheng)(sheng)原(yuan)理的(de)(de)不同可以(yi)分為(wei)阻性(xing)、抗性(xing)、共振型(xing)和(he)(he)復合型(xing)等。一、阻性(xing)消(xiao)(xiao)聲(sheng)(sheng)(sheng)器(qi),阻性(xing)消(xiao)(xiao)聲(sheng)(sheng)(sheng)器(qi)利(li)用(yong)吸(xi)聲(sheng)(sheng)(sheng)材(cai)料(liao)(liao)(liao)的(de)(de)吸(xi)聲(sheng)(sheng)(sheng)作用(yong)而消(xiao)(xiao)聲(sheng)(sheng)(sheng)的(de)(de)。其(qi)構(gou)造是(shi)把(ba)吸(xi)聲(sheng)(sheng)(sheng)材(cai)料(liao)(liao)(liao)固(gu)定在氣流(liu)流(liu)動的(de)(de)管道(dao)內壁,或按(an)一定方式排列在管道(dao)或殼體內構(gou)成阻性(xing)消(xiao)(xiao)聲(sheng)(sheng)(sheng)器(qi),吸(xi)聲(sheng)(sheng)(sheng)材(cai)料(liao)(liao)(liao)能(neng)夠把(ba)入射(she)在其(qi)上的(de)(de)聲(sheng)(sheng)(sheng)能(neng)部(bu)分地吸(xi)收(shou)掉(diao)(diao)。聲(sheng)(sheng)(sheng)能(neng)之所以(yi)能(neng)被吸(xi)收(shou),是(shi)由(you)于吸(xi)聲(sheng)(sheng)(sheng)材(cai)料(liao)(liao)(liao)的(de)(de)多孔(kong)(kong)性(xing)和(he)(he)松散性(xing)。當聲(sheng)(sheng)(sheng)波(bo)進入孔(kong)(kong)隙,引起孔(kong)(kong)隙中的(de)(de)空氣和(he)(he)材(cai)料(liao)(liao)(liao)產(chan)生微小的(de)(de)振動,由(you)于摩擦(ca)和(he)(he)粘滯阻力。使相(xiang)當一部(bu)分聲(sheng)(sheng)(sheng)能(neng)化(hua)為(wei)熱能(neng)而被吸(xi)收(shou)掉(diao)(diao)。

成都值得信賴的通風管道廠家

消防排煙機一般是采用離心式風機和軸流式風機兩種重要的型式。從消防排煙風機風量、風壓考慮來看,消防排煙風機是高比轉高效率的風機,更加的適合選用軸流風機。軸流式消防排煙風機有兩種設計型式,一種為電機與主氣流分離型式,另一種為電機置于主氣流之中。成都通風管道根據煙氣溫度的不同,采用不同型式的消防排煙風機,溫度大于400℃時,采用電機與主氣流分離型式,溫度小于400℃大于150℃,兩種型式的電機都可以選擇,在溫度小于150℃的時候,采用電機置于主氣流之中。 軸流消防排煙風機的流量范圍從7200m?/h至110000m?/h,有不同型號的編制,通風管道用(yong)來滿足(zu)(zu)不(bu)同(tong)通(tong)風(feng)(feng)(feng)排(pai)(pai)(pai)煙(yan)流(liu)量(liang)(liang)的(de)需求。消(xiao)(xiao)防(fang)排(pai)(pai)(pai)煙(yan)風(feng)(feng)(feng)機(ji)可以(yi)根據(ju)壓力(li)(li)情況的(de)不(bu)同(tong)分為(wei)兩種(zhong)類型,一類為(wei)軸流(liu)式消(xiao)(xiao)防(fang)排(pai)(pai)(pai)煙(yan)機(ji),其各機(ji)號(hao)的(de)壓力(li)(li)在600Pa左(zuo)右,另一類為(wei)斜(xie)流(liu)消(xiao)(xiao)防(fang)排(pai)(pai)(pai)煙(yan)風(feng)(feng)(feng)機(ji),各機(ji)號(hao)的(de)壓力(li)(li)在1000Pa左(zuo)右。為(wei)了(le)滿足(zu)(zu)排(pai)(pai)(pai)煙(yan)量(liang)(liang)和通(tong)風(feng)(feng)(feng)換氣的(de)要求,消(xiao)(xiao)防(fang)排(pai)(pai)(pai)煙(yan)風(feng)(feng)(feng)機(ji)一般都(dou)設計了(le)雙速(su)型的(de)結構模(mo)式。低(di)速(su)可以(yi)通(tong)風(feng)(feng)(feng)使用(yong),高速(su)可以(yi)排(pai)(pai)(pai)放(fang)煙(yan)霧,這樣不(bu)但可以(yi)節約能源(yuan)同(tong)時又降低(di)了(le)噪聲污染。

成都值得信賴的通風管道廠家

消防(fang)(fang)(fang)(fang)排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)風(feng)(feng)(feng)(feng)機風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)與送(song)風(feng)(feng)(feng)(feng)機風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)計(ji)(ji)算(suan)方(fang)(fang)(fang)(fang)法是(shi)(shi)根(gen)據(ju)建筑面(mian)(mian)積(ji)(ji)來確定的(de),每個防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu)都需(xu)要獨立計(ji)(ji)算(suan)其(qi)(qi)排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang),當排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)風(feng)(feng)(feng)(feng)機擔負一(yi)(yi)個防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu)的(de)時(shi)候可按(an)平(ping)(ping)方(fang)(fang)(fang)(fang)米(mi)(mi)面(mian)(mian)積(ji)(ji)不小(xiao)(xiao)于(yu)(yu)60m3/h計(ji)(ji)算(suan),擔負多個防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu)則按(an)平(ping)(ping)方(fang)(fang)(fang)(fang)米(mi)(mi)面(mian)(mian)積(ji)(ji)不小(xiao)(xiao)于(yu)(yu)120m3/h計(ji)(ji)算(suan)。送(song)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)按(an)排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)的(de)50%計(ji)(ji)算(suan)。每個防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu)不應大(da)(da)于(yu)(yu)500平(ping)(ping)方(fang)(fang)(fang)(fang)。常見的(de)消防(fang)(fang)(fang)(fang)防(fang)(fang)(fang)(fang)排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)系統中,排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)一(yi)(yi)般根(gen)據(ju)大(da)(da)防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu)面(mian)(mian)積(ji)(ji)500*120等于(yu)(yu)60000立方(fang)(fang)(fang)(fang)每小(xiao)(xiao)時(shi)計(ji)(ji)算(suan),在(zai)設計(ji)(ji)排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)的(de)時(shi)候要注意漏(lou)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang),一(yi)(yi)般可按(an)小(xiao)(xiao)漏(lou)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)10%計(ji)(ji)算(suan)。例如(ru):當建筑面(mian)(mian)積(ji)(ji)為1000平(ping)(ping)方(fang)(fang)(fang)(fang)時(shi),需(xu)要設置兩個防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu),每個防(fang)(fang)(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)分(fen)(fen)區(qu)的(de)大(da)(da)面(mian)(mian)積(ji)(ji)為500平(ping)(ping)方(fang)(fang)(fang)(fang),排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)是(shi)(shi)500*1203/h=600003/h,再加上小(xiao)(xiao)漏(lou)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)10%為60003/h,總排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)應為660003/h,其(qi)(qi)中送(song)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)為排(pai)煙(yan)(yan)(yan)(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)的(de)50%應為330003/h。

成都值得信賴的通風管道廠家

1.通(tong)風(feng)(feng)(feng)、空氣(qi)調節(jie)系統(tong)的(de)(de)(de)(de)風(feng)(feng)(feng)管(guan)(guan)(guan)(guan)在(zai)下列部位(wei)應設(she)(she)置(zhi)(zhi)公(gong)稱動作溫(wen)(wen)度為(wei)70℃的(de)(de)(de)(de)防火(huo)(huo)(huo)閥(fa)。①穿(chuan)越防火(huo)(huo)(huo)分區處(chu)(chu)(chu)(chu)。②穿(chuan)越通(tong)風(feng)(feng)(feng)空調機房(fang)的(de)(de)(de)(de)房(fang)間隔墻和樓板(ban)處(chu)(chu)(chu)(chu)。③穿(chuan)越重要或火(huo)(huo)(huo)災危險性大的(de)(de)(de)(de)場所的(de)(de)(de)(de)房(fang)間隔墻和樓板(ban)處(chu)(chu)(chu)(chu)。④穿(chuan)越防火(huo)(huo)(huo)分隔處(chu)(chu)(chu)(chu)的(de)(de)(de)(de)變形(xing)縫兩(liang)側。⑤豎向風(feng)(feng)(feng)管(guan)(guan)(guan)(guan)與(yu)每層水平風(feng)(feng)(feng)管(guan)(guan)(guan)(guan)交接(jie)處(chu)(chu)(chu)(chu)的(de)(de)(de)(de)水平管(guan)(guan)(guan)(guan)段上,當建筑內(nei)(nei)每個防火(huo)(huo)(huo)分區的(de)(de)(de)(de)通(tong)風(feng)(feng)(feng)、空氣(qi)調節(jie)系統(tong)均獨立設(she)(she)置(zhi)(zhi)時,水平風(feng)(feng)(feng)管(guan)(guan)(guan)(guan)與(yu)豎向總(zong)管(guan)(guan)(guan)(guan)的(de)(de)(de)(de)交接(jie)處(chu)(chu)(chu)(chu)可(ke)不設(she)(she)置(zhi)(zhi)防火(huo)(huo)(huo)閥(fa)。2.公(gong)共(gong)(gong)建筑的(de)(de)(de)(de)浴室、衛(wei)生(sheng)間和廚(chu)房(fang)的(de)(de)(de)(de)豎向排(pai)風(feng)(feng)(feng)管(guan)(guan)(guan)(guan),應采取(qu)防止(zhi)回流措施并宜在(zai)支管(guan)(guan)(guan)(guan)上設(she)(she)置(zhi)(zhi)公(gong)稱動作溫(wen)(wen)度為(wei)70℃的(de)(de)(de)(de)防火(huo)(huo)(huo)閥(fa)。公(gong)共(gong)(gong)建筑內(nei)(nei)廚(chu)房(fang)的(de)(de)(de)(de)排(pai)油煙管(guan)(guan)(guan)(guan)道(dao)宜按防火(huo)(huo)(huo)分區設(she)(she)置(zhi)(zhi),且在(zai)與(yu)豎向排(pai)風(feng)(feng)(feng)管(guan)(guan)(guan)(guan)連接(jie)的(de)(de)(de)(de)支管(guan)(guan)(guan)(guan)處(chu)(chu)(chu)(chu)應設(she)(she)置(zhi)(zhi)公(gong)稱動作溫(wen)(wen)度為(wei)150℃的(de)(de)(de)(de)防火(huo)(huo)(huo)閥(fa)。 3.排(pai)煙防火(huo)(huo)(huo)閥(fa)(280℃)的(de)(de)(de)(de)設(she)(she)置(zhi)(zhi)場所:①排(pai)煙管(guan)(guan)(guan)(guan)進入排(pai)風(feng)(feng)(feng)機房(fang)處(chu)(chu)(chu)(chu);②穿(chuan)越防火(huo)(huo)(huo)分區的(de)(de)(de)(de)排(pai)煙管(guan)(guan)(guan)(guan)道(dao)上;③排(pai)煙系統(tong)的(de)(de)(de)(de)支管(guan)(guan)(guan)(guan)上;