地址:重慶市(shi)江津區雙福新區福星大道(dao)937號鑫成瑞暖通廠區
一、風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)及(ji)部件安(an)裝(zhuang)的(de)有關規定1.風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)安(an)裝(zhuang)的(de)強制規定,當風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)穿(chuan)過需要(yao)封閉(bi)的(de)防(fang)(fang)火、防(fang)(fang)爆(bao)墻體或樓板(ban)時,應(ying)(ying)設(she)(she)預埋管(guan)(guan)(guan)或防(fang)(fang)護(hu)套管(guan)(guan)(guan)。套管(guan)(guan)(guan)鋼板(ban)厚度不(bu)應(ying)(ying)小(xiao)于1.6mm,風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)與防(fang)(fang)護(hu)套管(guan)(guan)(guan)之間應(ying)(ying)用不(bu)燃(ran)且對(dui)人體無害的(de)柔性材料封堵,風(feng)(feng)(feng)(feng)(feng)(feng)道應(ying)(ying)安(an)裝(zhuang)設(she)(she)防(fang)(fang)火閥。風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)內嚴禁各(ge)種管(guan)(guan)(guan)道、電(dian)線敷(fu)設(she)(she)及(ji)穿(chuan)越;輸(shu)送含(han)有易(yi)燃(ran)易(yi)爆(bao)氣(qi)體或安(an)裝(zhuang)在(zai)易(yi)燃(ran)易(yi)爆(bao)環境(jing)的(de)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)系(xi)統,應(ying)(ying)有良好的(de)接(jie)地,通過生活(huo)區(qu)、生產房間時必(bi)須嚴密,不(bu)得設(she)(she)接(jie)口;室外主管(guan)(guan)(guan)的(de)固定拉(la)索嚴禁拉(la)在(zai)避(bi)雷針或避(bi)雷網上。輸(shu)送溫度高于80℃的(de)空(kong)氣(qi)的(de)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan),應(ying)(ying)按(an)設(she)(she)計要(yao)求采取防(fang)(fang)護(hu)措(cuo)施(shi)。2.風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)安(an)裝(zhuang)的(de)一般規定風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)安(an)裝(zhuang)宜(yi)在(zai)建筑圍(wei)護(hu)結構施(shi)工(gong)完畢、場所清(qing)理后(hou)(hou)進行。凈化空(kong)調風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)應(ying)(ying)在(zai)安(an)裝(zhuang)部位地面(mian)做好,墻面(mian)抹(mo)灰工(gong)序完畢,室內無飛(fei)塵(chen)或有防(fang)(fang)塵(chen)措(cuo)施(shi)后(hou)(hou)進行。安(an)裝(zhuang)風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)前應(ying)(ying)清(qing)除(chu)管(guan)(guan)(guan)內外雜物,并(bing)做好清(qing)潔和(he)保護(hu)工(gong)作,風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)安(an)裝(zhuang)的(de)位置、標高和(he)走向等應(ying)(ying)符合設(she)(she)計要(yao)求,現場風(feng)(feng)(feng)(feng)(feng)(feng)管(guan)(guan)(guan)接(jie)口的(de)配(pei)置不(bu)得縮小(xiao)有效截面(mian)。
消防(fang)(fang)排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)風(feng)(feng)(feng)(feng)機(ji)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)與送(song)風(feng)(feng)(feng)(feng)機(ji)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)計(ji)(ji)算(suan)(suan)(suan)方法是(shi)根據(ju)建筑(zhu)面(mian)(mian)(mian)積來確(que)定(ding)的(de)(de)(de),每(mei)(mei)個防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區都需要獨立(li)計(ji)(ji)算(suan)(suan)(suan)其(qi)排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang),當排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)風(feng)(feng)(feng)(feng)機(ji)擔(dan)負(fu)一(yi)個防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區的(de)(de)(de)時候可(ke)按平方米(mi)(mi)面(mian)(mian)(mian)積不(bu)小于(yu)60m3/h計(ji)(ji)算(suan)(suan)(suan),擔(dan)負(fu)多個防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區則(ze)按平方米(mi)(mi)面(mian)(mian)(mian)積不(bu)小于(yu)120m3/h計(ji)(ji)算(suan)(suan)(suan)。送(song)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)按排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)的(de)(de)(de)50%計(ji)(ji)算(suan)(suan)(suan)。每(mei)(mei)個防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區不(bu)應大(da)于(yu)500平方。常見的(de)(de)(de)消防(fang)(fang)防(fang)(fang)排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)系統(tong)中,排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)一(yi)般(ban)根據(ju)大(da)防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區面(mian)(mian)(mian)積500*120等(deng)于(yu)60000立(li)方每(mei)(mei)小時計(ji)(ji)算(suan)(suan)(suan),在(zai)設計(ji)(ji)排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)的(de)(de)(de)時候要注意漏風(feng)(feng)(feng)(feng)量(liang)(liang)(liang),一(yi)般(ban)可(ke)按小漏風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)10%計(ji)(ji)算(suan)(suan)(suan)。例如:當建筑(zhu)面(mian)(mian)(mian)積為(wei)1000平方時,需要設置兩個防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區,每(mei)(mei)個防(fang)(fang)煙(yan)(yan)(yan)(yan)(yan)分(fen)區的(de)(de)(de)大(da)面(mian)(mian)(mian)積為(wei)500平方,排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)是(shi)500*1203/h=600003/h,再加上小漏風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)10%為(wei)60003/h,總排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)應為(wei)660003/h,其(qi)中送(song)風(feng)(feng)(feng)(feng)量(liang)(liang)(liang)為(wei)排(pai)(pai)(pai)煙(yan)(yan)(yan)(yan)(yan)量(liang)(liang)(liang)的(de)(de)(de)50%應為(wei)330003/h。
1.通風、空氣調節系統的風管在下列部位應設置公稱動作溫度為70℃的防火閥。①穿越防火分區處。②穿越通風空調機房的房間隔墻和樓板處。③穿越重要或火災危險性大的場所的房間隔墻和樓板處。④穿越防火分隔處的變形縫兩側。⑤豎向風管與每層水平風管交接處的水平管段上,當建筑內每個防火分區的通風、空氣調節系統值得信賴的消防通風設備均獨立設置時,水平風管與豎向總管的交接處可不設置防火閥。2.公共建筑的浴室、衛生間和廚房的豎向排風管,消防通風設備批發應采取防止回(hui)流(liu)措施并宜(yi)在支管(guan)(guan)(guan)上設置公稱動作(zuo)溫(wen)度為(wei)70℃的(de)防火(huo)(huo)閥。公共建筑內(nei)廚房的(de)排(pai)油(you)煙(yan)管(guan)(guan)(guan)道宜(yi)按(an)防火(huo)(huo)分區設置,且在與(yu)豎(shu)向排(pai)風(feng)管(guan)(guan)(guan)連接(jie)的(de)支管(guan)(guan)(guan)處(chu)應設置公稱動作(zuo)溫(wen)度為(wei)150℃的(de)防火(huo)(huo)閥。 3.排(pai)煙(yan)防火(huo)(huo)閥(280℃)的(de)設置場(chang)所:①排(pai)煙(yan)管(guan)(guan)(guan)進入排(pai)風(feng)機(ji)房處(chu);②穿越防火(huo)(huo)分區的(de)排(pai)煙(yan)管(guan)(guan)(guan)道上;③排(pai)煙(yan)系統的(de)支管(guan)(guan)(guan)上;
排(pai)(pai)(pai)(pai)煙(yan)(yan)閥(fa)(fa)(fa)是否(fou)存在常(chang)開的(de)(de)(de)(de)?這里的(de)(de)(de)(de)排(pai)(pai)(pai)(pai)煙(yan)(yan)閥(fa)(fa)(fa)也(ye)就相當于排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou),對于常(chang)見的(de)(de)(de)(de)板式排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou)與多(duo)葉排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou),市場上(shang)(shang)常(chang)見的(de)(de)(de)(de)均(jun)為(wei)常(chang)閉形(xing)式,一般(ban)不(bu)需要(yao)常(chang)開的(de)(de)(de)(de)排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou)。對于排(pai)(pai)(pai)(pai)風(feng)(feng)(feng)兼排(pai)(pai)(pai)(pai)煙(yan)(yan)系(xi)統的(de)(de)(de)(de)排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou),可以(yi)采用“單層(ceng)(ceng)百葉 + 280 ℃ 電控排(pai)(pai)(pai)(pai)煙(yan)(yan)防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)”進(jin)行控制。70 ℃防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)的(de)(de)(de)(de)應用場合(he)有哪些?防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)應用場合(he)很(hen)多(duo),在空(kong)調送回(hui)風(feng)(feng)(feng)干管(guan)(guan)(guan),通風(feng)(feng)(feng)風(feng)(feng)(feng)機進(jin)出口(kou)(kou),風(feng)(feng)(feng)井入口(kou)(kou),管(guan)(guan)(guan)道穿越防(fang)火(huo)(huo)(huo)分區(qu) / 變形(xing)縫 / 重要(yao)房(fang)間(jian) / 機房(fang) / 火(huo)(huo)(huo)災危險(xian)性(xing)大的(de)(de)(de)(de)房(fang)間(jian)的(de)(de)(de)(de)隔墻或樓(lou)板,垂(chui)直風(feng)(feng)(feng)管(guan)(guan)(guan)與每層(ceng)(ceng)水(shui)平風(feng)(feng)(feng)管(guan)(guan)(guan)連(lian)接處。等很(hen)多(duo)場合(he)都需要(yao)設置防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)。 空(kong)調新風(feng)(feng)(feng)取(qu)風(feng)(feng)(feng)管(guan)(guan)(guan)是否(fou)需要(yao)安裝(zhuang)防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)?一般(ban)不(bu)需要(yao)。特別是如果回(hui)風(feng)(feng)(feng)、送風(feng)(feng)(feng)均(jun)安裝(zhuang)防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)之后,新風(feng)(feng)(feng)取(qu)風(feng)(feng)(feng)口(kou)(kou)就沒有必要(yao)在安裝(zhuang)防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)了。并(bing)且一般(ban)取(qu)風(feng)(feng)(feng)口(kou)(kou)位于室外,且按照(zhao)規范要(yao)求與排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou)保持10 m以(yi)上(shang)(shang)的(de)(de)(de)(de)水(shui)平距(ju)離(li)或3 m以(yi)上(shang)(shang)的(de)(de)(de)(de)垂(chui)直距(ju)離(li)( 排(pai)(pai)(pai)(pai)煙(yan)(yan)口(kou)(kou)在上(shang)(shang) ),一般(ban)煙(yan)(yan)氣不(bu)會從新風(feng)(feng)(feng)口(kou)(kou)進(jin)入空(kong)調,所(suo)以(yi)一般(ban)不(bu)需要(yao)安裝(zhuang)防(fang)火(huo)(huo)(huo)閥(fa)(fa)(fa)。